WGC-BREF

The WGC-BREF is the Best Available Techniques reference document for Common Waste Gas Management and Treatment Systems in the Chemical Sector. It sets out requirements and environmental performance levels for the treatment of waste gases generated by various chemical processes. One of the main objectives of the WGC-BREF is to define and harmonize the so-called Best Available Techniques (BAT) for air pollution control at industrial installations.

The WGC BAT conclusions were published in the Official Journal of the European Union on 12 December 2022. As existing installations are subject to a strict four-year implementation period, the deadline for mandatory compliance expires in December 2026.

For operators of chemical plants, this means that the requirements of the WGC-BREF are binding and must be taken into account when planning new installations, obtaining permits and operating existing plants. The reference document serves both authorities and plant operators as a benchmark for technical standards and emission limit values.

Position within the regulatory framework: from the IED to TA Luft

The WGC-BREF forms part of the European and German regulatory framework for environmental protection. At EU level, the document is based on the Industrial Emissions Directive (Directive 2010/75/EU, as amended by Directive (EU) 2024/1785), which aims to achieve consistently high environmental standards for industrial installations throughout Europe. The IED requires Member States to apply Best Available Techniques and comply with the emission levels associated with best available techniques (BAT-AELs).

BREFs – including the WGC-BREF – are developed with the participation of industry, public authorities and environmental organizations. Following publication, their requirements must be implemented at national level within four years.

In Germany, implementation is based on the Federal Immission Control Act (Bundes-Immissionsschutzgesetz – BImSchG) and the Technical Instructions on Air Quality Control (TA Luft). [JM1.1]TA Luft incorporates relevant requirements from the WGC-BREF relating to waste gas treatment systems in the chemical industry. Additional regulations, such as the German Waste Water Ordinance and individual ordinances under the BImSchG, may also apply.

The WGC-BREF is therefore not an isolated technical document but part of a binding regulatory framework. It defines detailed requirements for waste gas treatment systems used in specific chemical industry processes. One key element is the environmental performance levels for emissions to air. These specify emission ranges in µg/l or mg/m³ that are to be achieved through the application of Best Available Techniques.

Scope of the WGC-BREF

The WGC-BREF generally applies to all large-scale chemical industry installations falling within the scope of Annex I, Sections 4.1 to 4.6, of the EU Industrial Emissions Directive (IED).

These include, among others, the following types of installations:

  • Organic chemicals (Section 4.1)
  • Inorganic chemicals (Section 4.2)
  • Phosphorus-, nitrogen- or potassium-based fertilizers (Section 4.3)
  • Plant protection products and biocides (Section 4.4)
  • Pharmaceutical products (Section 4.5)
  • Explosives (Section 4.6)

The WGC-BREF does not, however, cover:

  • Waste incineration (WI-BREF)
  • Chlor-alkali production (CAK-BREF)
  • Refineries and large combustion plants
  • Flare emissions and diffuse emissions
  • Storage, transfer and material handling

These areas are regulated on the basis of other reference documents.

Technical implementation and monitoring

Technical implementation is based on compliance with the BAT-AELs specified in the WGC-BREF. Operators are required to use continuous emission monitoring (CEM) systems where defined mass flow thresholds are exceeded. Parameters monitored include NOx, CO, particulate matter and organic compounds.

The resulting measurement data must be reported regularly to the competent environmental authorities. Reports demonstrating compliance with BAT requirements must be structured, transparent and properly documented.

Implementation in industry

Plant engineering companies such as Wessel-Umwelttechnik provide modular technical solutions designed to meet WGC-BREF requirements.

These include:

  • Industrial air scrubber systems for HCl, HF, SO₂ and NH₃
  • • RTO systems, biofilters and adsorption systems for VOC reduction
  • SCR modules for NOx reduction

These technical solutions are used not only in the chemical industry but also in related sectors such as the pharmaceutical industry and plastics manufacturing.

Impact on industry

Implementing the WGC-BREF requirements initially entails increased investment for companies, particularly where existing installations need to be retrofitted or upgraded.

In the long term, however, this can provide a number of benefits:

  • Reduced operating costs through more efficient technologies
  • Improved environmental performance and corporate image
  • Preparation for future regulatory requirements
  • Competitive advantages through forward-looking environmental strategies

Importance of the WGC-BREF for environmental technology and industry

The WGC-BREF is a key instrument for harmonizing and improving industrial emission control in the chemical industry. It establishes binding technical standards, provides clear requirements for plant operators and, at the same time, promotes innovation in environmental technology.

For companies, this means that consistent implementation of the WGC-BREF requirements is essential for maintaining regulatory compliance while operating efficiently and sustainably over the long term. Modern environmental technology – such as the solutions provided by Wessel-Umwelttechnik – provides the practical systems required to meet these challenges.

Other technologies or applications

Contact Form
Control Act (BImSchG)

The Immission Control Act of Germany is a legal framework that aims to protect the environment and people from harmful effects. These effects, also known as immissions, can …

Odour Immission 
Guideline

The odour immission guideline (in German: Geruchsimmissionsrichtlinie, abbreviated as: GIRL) regulates the assessment of odour immissions to protect …

Technical Instructions on Air Quality Control – TA Luft

The Technical Instructions on Air Quality Control (in German: Technische Anleitung zur Reinhaltung der Luft, abbreviated as: TA Luft) are a central administrative regulation …

IED – 
Industrial Emissions Directive

The Industrial Emissions Directive (IED) is an EU directive designed to limit emissions and environmental pollution from industrial installations across Europe ...

Important Notice

The information provided in our Info Center on legal requirements and regulations governing exhaust air purification is intended solely for general guidance and does not constitute legal advice. 

Wessel-Umwelttechnik provides customized solutions for legally compliant exhaust air purification, tailored to the specific requirements of each industry and company. Please do not hesitate to contact us. Together, we will identify the optimal technology for your requirements and support you in complying with all applicable regulations.

Contact Form

Do you have any further questions? Please feel free to contact us.

Kontaktformular

Daten
Please feel free to contact us!
captcha
Fields marked with * are mandatory.